IBM Hardware Management Console Best Practices Ron Barker Minh Nguyen Shamsundar Ashok January 2007

Strona 2

Hardware Management Console Best Practices

Strona 3

Table of Contents 1 Overview 5 2 Planning 6 2.1 Do I Need an HMC? 6 2.2 HMC Models 6 2.3 Physical Location of an HMC 7 2.4 Planning for Network…

Strona 4

7.1 Remote command 40 7.7.2 Network Installation/Update/Backup/Restore 41 7.7.3 Server setup 41 7.8 Startup the HMC Using the Network 43 7.9…

Strona 5 - 1 Overview

1 Overview This paper is a compilation of useful information, recommendations and best practices for managing the IBM Hardware Management Console…

Strona 6 - 2 Planning

2 Planning should be done for any major change in any computing environment, including adding new servers, performing upgrades and implementing…

Strona 7

The number of servers each HMC can manage varies by server size and complexity. Each server partition will have a connection to an Ethernet network…

Strona 8

A server with dual HMCs would be connected to two private networks with each HMC acting as a DHCP server on a unique, non-routable subnet. In order to…

Strona 9

reasons. If no laptop is available, an ASCII terminal can be used on the native serial port to access the FSP menus in character mode. Open networks…

Strona 10

Updates can be downloaded over the Internet for workstation-based installations. The online version can be accessed at this URL…

Strona 11 - 3 Initial Configuration

3 Initial Configuration HMCs come with Licensed Machine Code preinstalled, but you may need to reinstall if the code has been superseded or you have a…

Strona 12

3 Creating User IDs Additional user IDs should be created on the HMC so that not every user is accessing the system with the same user ID and…

Strona 13

tunneling, the HMC’s IP address was exposed. At HMC V5R2, support was added for outbound, SSL socket based communications, and as of HMC V6R1, proxy…

Strona 14 - 4 Security

4 Security Physical security of the HMC is a customer responsibility. The HMC should be located in a secure room, if possible. Usually, because of its…

Strona 15

2 Secure WebSM A secure WebSM connection using Secure Socket Layer (SSL) code is also available on the HMC. The SSL code can also be downloaded as…

Strona 16

The following command disables all remote WebSM connections to the HMC: $ chhmc –c websm –s disable The following command disables the HTTP service on…

Strona 17

4.1 Power 5 HMC port information Port Protocol Application Enabled by Default Modification allowed in Network Config Security NOTES 9090, 9940, 30000…

Strona 18

The firewall interface allows you to customize remote access to the HMC by IP address and network mask. An example of the customization screen is…

Strona 19

Because the full list of HMC commands is published at the IBM HMC’s web site, we will only reference a few security-related commands in this paper.…

Strona 20

lssvcevents -t console Earliest Timestamp Description 10/16/03 07:27:51 PM HSCE2175 User hscroot login failed from remote host abcd.xyz.com with IP…

Strona 21

# ssh hscroot@stratus mkauthkeys -a -u minh '"command=\"logssh \${SSH_ORIGINAL_COMMAND}\" ssh- rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzxTNjoXAvyZBw390oJ27uj…

Strona 22

HMC for establishing a trusted communication channel between the HMC and the partitions on the managed server. Some of the tasks performed through…

Strona 23 - 5 User Management

5 User Management The HMC provides a User Management facility to create and manage users, as well as control their access to HMC tasks and managed…

Strona 24

To manage users employing the HMC WebSM console, a user with hmcsuperadmin authority would go to the HMC Management -> HMC Users plugin. There, select…

Strona 25

2 Task and Managed Resource Roles As mentioned in the introduction to this section, a role is a way of grouping access privileges. On the HMC, roles…

Strona 26

hscroot@myhost:~> lshmcusr --filter names=hscroot name=hscroot,taskrole=hmcsuperadmin,description=,pwage =99999,resourcerole= From the HMC console as…

Strona 27

520*10007CA|IBMHSC_Partition,lpar:root/ibmhscS1_0|3*9 406- 520*10007CA|IBMHSC_Partition,lpar:root/ibmhscS1_0|6*9 406…

Strona 28

# create a resource role for a managed system and LPAR # resource type; note that the managed system includes # the LPARs, so adding ALL_PARTITIONS is…

Strona 29

Thus, while it is unlikely to occur, it would be a good practice to document customized roles and to pay attention to the REAME files that come with…

Strona 30 - 6 Problem Determination

6 Problem Determination This section is intended to cover issues and problems that may be encountered during operation of the HMC itself. While some…

Pokaż wszystkie strony (57)
Strona 31

-c Collect trace files and (optional) stack traces of various subsystems. This initiates an interactive task which will prompt for verification if…

Strona 32

This password is valid until the end of the calendar day for which it was issued. Hence, a password obtained at 11 pm will expire in one hour, i.e.…

Strona 33

C03 desktop model, or 7310-CR2 / 7310-CR3 rack-mount models, make sure the hyperthreading option under the Advanced options in BIOS is disabled. On…

Strona 34

Incomplete: The HMC is unable to gather all system information from the managed system or frame. In some cases this could be due to a network error…

Strona 35

Another observed problem has been the GUI isn’t reflecting the true managed system or frame status or configuration. The CLI can be used to see if it…

Strona 36

7 Maintaining Licensed Internal Code Make sure you keep track of new releases, updates and emergency fixes to HMC code. You can do this in one of two…

Strona 37

2 HMC Code Installation/Upgrade/Update HMC systems leave manufacturing pre-installed with the most recent level of code. However, there may be time…

Strona 38

5 Update (Corrective Service) In between HMC releases, or between upgrades, there will be times when interim fixes or cumulative service packs need to…

Strona 39

Corrective service is a cumulative maintenance release within a single version that customers can use to update the HMC from any previous releases…

Strona 40 - 7.7.1 Remote command

Temporary Fix) value associated with the interim fix or service pack when using a command such as lshmc –V, for example: MH00324: Maintenance Package…

Strona 41 - 7.7.3 Server setup

7.2 Network Installation/Update/Backup/Restore Beginning with Version 5 Release 1.0, you can select the integrated network adapter in your HMC as a…

Strona 42

This file is part of the syslinux package and should be copied from /usr/lib/syslinux/ to /var/tftp/ directory. Create the following directories…

Strona 43

File Name Location on Media Directory to copy to disk1.img Media 1: base/ /home/hmc/images/ disk2.img Media 1: images/ /home/hmc/images/ disk3.img…

Strona 44

F12 and select the network device as the startup device for this boot instance. NOTE: In a future release of HMC, there will be enhancements made to…

Strona 45 - 7.9.1 Server setup

If you have more than one network card on your HMC, select Default if the install images reside on the same server to which the HMC sent PXE requests.…

Strona 46

specified, however the full hostname with domain should be specified. xdir Directory or File name Directory or Full path of file to backup to or…

Strona 47 - 7.9.3 Preparing the HMC

9.3 Preparing the HMC Once the server is set up, follow the steps below to prepare the HMC. If the HMC is currently running, then you must first shut…

Strona 48

while HMC B may choose to contact the same server with user intervention. In addition, HMC B has multiple Ethernet adapter cards, requiring it to…

Strona 49

8 Tips for Maintaining Licensed Internal Code Make sure you keep track of new releases, updates and emergency fixes to HMC code. You can do this in…

Strona 50

9 Tips for Maintaining System Firmware on the Managed System The naming convention for system firmware updates is as follows: 01SFXXX_YYY_ZZZ XXX is…

Strona 51

2 Concurrent versus Disruptive Updates Starting with HMC V4R5, the behavior of the code update wizard on the HMC changed. The new behavior favors…

Strona 52

Hardware Management Console Best Practices

Strona 53 - Appendix I

Appendix I The HMC does not have any Active Directory or LDAP support for automated user management. In large environments with many servers, there…

Strona 54

{ echo "hmcusers: -o [ add | delete ] -h <list of hmc hosts>" echo " -l <login> -u <list of user names> - a <hmc access>" echo " -o The operation to…

Strona 55

echo "user names not specified" usage fi if [ "$op" == "add" ]; then # some validation here if [ "$access" == "" ]; then echo "missing HMC access…

Strona 56

if [ $? -eq 0 ]; then echo "Deleted user "$u" on "$i else echo "Failed to delete user "$u" on "$i fi done done fi For more information about the tasks…

Strona 57

© IBM Corporation 2005 IBM Corporation Systems and Technology Group Route 100 Somers, New York 10589 Produced in the United States of America March…

Więcej dokumentów dla Oprogramowanie programistyczne Do+Able Products 12347

Pytania o Do+Able Products 12347

Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.

Zadaj pytanie

Odpowiadamy na podstawie instrukcji i wskazujemy stronę. Pytanie pojawi się w serwisie po sprawdzeniu.

Wszystkie pytania i odpowiedzi ›

Powiązane produkty i podręczniki dla Oprogramowanie programistyczne Do+Able Products 12347